DJ Med DWC900 V3.0(High quality real time 4D color doppler) Ultrasound

R248,950.00

Complete High End Diagnostic system.

This item may take 3-4 weeks to deliver

SKU: DWC900 Category:

Description

Equipment profile

Appearance

Display: multipositional Moving 19” LCD

Control Second Display: 10.4” touch screen monitor

Power supply

Power: (AC) 220V±22V 50Hz±1Hz

Input power: 350VA

Safety classification

Protection against harmful ingress of water?

Protection against electric shock : Class I.

Degree of protection against electric shock: Type BF.

IPX1  the probe cable?IPX1

IPX7  the traducer of the probe?IPX7

 

Scope of application

  • General and Special (Vascular)
  • Obstetrics and Gynecology
  • Musculoskeletal system
  • Abdomen
  • Urology
  • Vascular and Peripheral vessels
  • Small parts (including breasts, thyroid, testis, etc.)
  • Cardiac

 

Scanning mode

Electronic linear, electronic convex, Electronic phased array

 

Mode of display

Black-and-white image: B, 2B, 4B, right/left B|M, B|D, right/left PW(D), top/down PW(D), M, B mode local amplification, linear probe trapezoidal imaging, 3D reconstruction

Blood flow images: spectrum: B/BC, BC/B, B/D, B/C/D CFM: B|C|D, B|C|M, B|C double real-time, PW(D), CFM, CPA, Power doppler

Color Doppler: color mapping, Tissue harmonic imaging, image enhancing algorithm.

Mode of display: energy, velocity, variance (in support of velocity variance), frequency, gain

Display control: the size and position of the sampling box are adjustable, the emitting angle of the linear probe is adjustable.

 

Spectral Doppler:

Sampling volume and position are adjustable

PW(D) tracing supports maximum and average velocity. The threshold of the maximum velocity is adjustable. Scanning scope: above base-line, below base-line and entire scanning.

PW(D) sound can be turned on or off, and can be regulated in volume. Velocity measuring: in support of maximum and minimum velocity

Parameters for control of blood flow color images: Doppler frequency, position and size of sampling box, base line, color gain, deflection angle, wall filter, accumulative number of times, etc.

Color depth of display

Continuously adjustable

Focusing

Electronic focusing + sound lens focusing

Emission involves single focus, double focuses, triple focuses, and quadruple focuses

Continuously dynamic focusing in receiving

Formation of digital beam

Continuously dynamic focusing

Dynamic aperture diameter

Weighted sum of reception delay

In support of semi-moment scanning, and ±10°linear reception deflection angle

Multi-beam processing

Signal processing/Doppler sound

Dynamic wave filtering

Quadrature demodulation

Total gain control

Composite gain technology: 8-section TGC and D-AGC.

Low-pass filter

Secondary sampling

Acoustic output adjustment

Adjustable Doppler stereophonic acoustic output

Image processing

Dynamic scope variation and logarithmic compaction

Time filtering

Space filtering

Frame average

Fringe enhancement

Gray scale variation

B|M- or M-mode scanning speed

Linear density control

Scanning angle/width control

Image optimization

Upward and downward Image flipping

Multi-angle image rotation

Options for color gray-scale bar inversion

Combined processing of tissue and flow images

Resolution of black-and-white images: 1024×768×8 bits (256 gray-scale)

Resolution of color images: 8 bit×8 bit×8 bit color coding

Selection of specific images

Optimized items are available to choose from

Basic measuring and calculating functions

2D normal measurement: distances, angle, perimeter, area (ellipse and locus methods), volume, volume – 3-line method (length, width, height), histogram, cross-section chart

Basic M-Mode measurement: time, distance, heart rate, valve rate

Obstetric measurement

With 4 varieties of obstetric databases for reckoning gestation age

3 non-editable versions: Asian, European and American, plus 1 editable version: user-customized.

The gestation age can be reckoned by the information in each version on gestational sac diameter, crown-rump length, biparietal diameter, head circumference, abdominal circumference, femur length, humerus length, abdominal transversal diameter, length of vertebrae, occipital-frontal diameter, cerebellum diameter, fibula length, radius length, Cisterna Magna, inner orbital diameter, output orbital diameter, amniotic fluid index, fetal heart rate, nuchal transparency, distance and area, etc.

 

Obstetric report

Measurement and calculation of amniotic fluid index (AFI)

Ratio calculation (BPD/OFD, FL/AC, FL/BPD and HC/AC)

Fetus weight estimation

Reckoning the gestation age and EDD by LMP and BBT

Fetal biophysical score

Fetal growth curve

Andrology measurement and calculation

Measurement and calculation of prostate and testis

Calculation of predicted prostatic specific antigen (PPSA) and Prostatic Specific Antigen density (PSAD).

Gynaecology measurement

Measurement and calculation of the uterus, left ovarium, right ovarium, left folliculus, right folliculus, etc.

Urology measurement and calculation

Detection and calculation of the left kidney, right kidney, bladder, residual urinal vol, etc.

Vessel measurement and calculation

Measurement and calculation of area stenosis rate and vascular stenosis rate.

Multi-fetus detection and measurement

Detection of multiple fetuses

Small parts detection and calculation

Detection and calculation of thyroid, galactophore, masses, etc.

Cardiac detection and calculation functions

Cardiology measurement software package—contains features of analyzing and measuring aorta, mitral valve, (left/right) ventricles, etc.

Area stenosis percentage (% area sten), tube diameter stenosis percentage (% Diam Sten)

Body surface area (BSA)

Body mark

In terms of bodily function, an body mark database is divided into several parts: abdomen, andrology, cardiology, gynecology, musculoskeletal, obstetrics,

pediatric, small parts, urology, etc.

 

Screen-displayed information

Probe conditions, mode of display, depth, focus, dynamic range, body marks, probe position marker, acoustic output, patient conditions, name of medical agency, measured value, time and date, scale, scanning direction, gray-scale curve, current working frequency of the probe, frame frequency, B-Mode total gains, C-Mode total gains, Mode-D total gains, menu, annotations, gray-scale belt, puncture guide line, TI (thermal index), MI (mechanical index)

Storage

Probe parameter storage

Image storage

Cine loop storage

Measurement results storage

Report storage

Cine loop

Automatic cine-loop

Manual cine-loop

Cine-loop speed setting

Cine-loop search

Frame-by-frame forward/backward cine-loop

Gray-scale

256 gray-scale

 

Language interface

Chinese and English available

 

Function of the trackball

Performing various operations based on the working state and menu

Controlling multiple electronic scale, locating the cursor, completing measurement

 

Input/output port Achieving: USB. BW printer, CR/RW

VGA output port

DVI output port

Network port

USB port

Video port (for B/W printer)

CR/RW.

DICOM

 

Ultrasound Probe technical specifications

Physical Number of channels 128

 3.5MHzR65 multi-frequency convex probe (128 channels) , 192 crystals

The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode, have a scanning angle of 60°. In the M-Mode, it can activate a particular array element as fixed-frequency probes. It can be used in the combination of B-Mode and M-Mode.

Scope of application: examination and diagnosis of abdominal tissues (liver, gallbladder, spleen, pancreas, kidneys, gastro-intestinal, uterus, urinary bladder, prostate, etc.), assessment of growth and maturity of the fetus in obstetric diagnosis.

 

Endocavity probes (transvaginal and transrectal)

6.5MHzR10 multi-frequency convex probe (128 channels) , 192 crystals

The probes have a frequency range between 5.0MHz-9.0MHz. In the B-Mode , they have a scanning angle of 140-158°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.

Scope of application: vagina, uterus, rectum, rectum wall, prostate, etc.

Warning: A sterile rubber sleeve must be used with this probe. The probe should not be activated before examination.

 

7.5MHzL46 multi-frequency linear probe (128 channels), 192 crystals

Frequency range between 6.0MHz-12.0MHz.  In the B-Mode, has a scanning width of 38-45°.  In the M-Mode, it can activate a particular array element as a fixed-frequency probe.  Can be used in the combination of B-Mode and M-Mode.

 

 7.5MHz multi-frequency rectal probe (128 channels), 192 crystals

Frequency range between 6.5MHz-8.5MHz. In the M-Mode,  can activate a particular array element as a fixed-frequency probe.  Can be used in the combination of B-Mode and M-Mode.

Scope of application: Rectum

Optional functions

Capability to add different options eg:

DICOM, Stress Echo, Elastography, can also be added after purchase.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.